Accutech   (accutech.pdf)

Wireless Instruments

 

   

           Wireless Instruments                             Base Station

The Accutech line of wireless instrumentation products enables cost-effective, easy and robust implementation of wireless sensor networks. If you require dedicated wireless I/O approved for Class 1 Div 1 or Class 1 Div 2 applications, use Accutech line of wireless instrumenation products.

Field Units integrate a variety of transducers with 902-928 Mhz, License-free, Spread Spectrum communications in a robust, battery powered package designed for operation in harsh industrial environments.

All Field Units transmit their signals back to a Base Station Unit where it is available as Modbus RTU or, with the addition of optional I/O modules, as analog or discrete outputs. See Table 1 and 2 below for the range of available Field and Base Units.

            Table 1: Available Field Units & Accessories

Model

Input

Range / Description

WI-RT-I

Integral RTD

-200 to 200 Deg. C. Lo or -200 to 482 Hi for 100 Ohm Platinum RTD

WI-RT-S

External RTD and 1 Discrete Input

-200 to 200 Deg. C. Lo or -200 to 482 Hi for 100 Ohm Platinum RTD

WI-TC-I

Integral Thermocouple

Thermocouple Type B,C,E,J,K,L,N,R,S,T,U

WI-TC-S

2 External Thermocouple and 2 Discrete Inputs

Thermocouple Type B,C,E,J,K,L,N,R,S,T,U

WI-GP-I

Gauge Pressure

30 to 5,000 PSIG

WI-AP-I

Absolute Pressure

30 to 300 PSIA

WI-DP-I

-XXXXXX

Differential Pressure

various models with limits up to 300 PSI

WI-AI

Current Input

Two 4-20mA loops

WI-AV

Voltage Input

Two 0-10V voltage

WI-AM

Acoustic/Ultrasound

 40Khz +/- 2.5Khz

WI-ANT-P6-A-10

 

10 ft. Antenna Extension Cable with Lightning Arrestor

WI-ANT-P6-A-25

 

25 ft. Antenna Extension Cable with Lightning Arrestor

-Y6

 

a 7.1 dB YAGI option is available to any of the Field Units on a YELLOW ROW above.

 

Each Base Station  radio can support up to 50 remote Field Units in a Point-to-Multipoint wireless sensor network. Furthermore, many Base Units can be networked together on an RS-485 bus, enabling a SCADA host to poll many sensor networks via Modbus RTU.

If only I/O is desired at the Master site, optional DIN-Rail mounted I/O modules can be configured via the WIM software. The WIM software maps the field signal to either an analog or discrete output available at the output of the I/O module. See Table 2 below for Base Station Units and Accessories.

  Table 2: Available Base Station Units & Accessories

Model

Description

WI-BR-I-XP

Base Station Radio with Explosion Proof Housing (Nema 4) and RS-485 Interface

WI-BR-R10-4X

Base Station Radio with Nema 4X housing, 10 ft. extension cable, 6 dB Omni antenna and RS-485 Interface

WI-BR-R25-4X

Base Station Radio with Nema 4X housing, 25 ft. extension cable, 6 dB Omni antenna and RS-485 Interface

WI-4AO

I/O Module - Analog Output - 4 4-20mA for above Base Radio

WI-8SW

I/O Module - Discrete Output - 8 DO for above Base Radio

WI-4AO-8SW

I/O Module - Mixed Outputs - 4 4-20mA & 8 DO for above Base Radio

WI-BR-I-XP-AO

Base Sation Radio with single 4-20mA Analog Output

WI-BR-I-XP-MOD

Base Station Radio with Modbus RTU over RS-485 (Use IPGateway or other similar device to convert Modbus RTU to Modbus TCP or Modbus over TCP for IP or Ethernet transmission)

WI-BR-R10-4X-MOD

Base Station Radio with Modbus RTU over RS-485 with 10 ft. extension cable and 6dB omni antenna, Nema 4X

WI-BR-R25-4X-MOD

Base Station Radio with Modbus RTU over RS-485 with 25 ft. extension cable and 6dB omni antenna, Nema 4X

WIM

Software - Windows-based Configuration and Network management

 

 Features
  • License-Free 902-928 MHz Spread Spectrum with up to 1.5 miles range LOS with high gain antennas at 19.2KBaud
  • Variety of transducers available (see above Table)
  • Point-to-Multipoint with up to 50 stations
  • Field Units are battery-powered with up to 5 year life using factory default configuration
  • Base Station Units and I/O modules operate from 24VDC/200mA or optional AC power
  • Base Station Unit Interface: RS-485 / Modbus RTU
  • Nema 4, 4X rated depending on unit
  • FM approved for Class I, Div 1 and Class 1, Div 2 Hazardous Location
  • -40 to 85 Deg. C Operating Temp.
  • Integral LCD Display showing process variable data/history and battery status/communication error/RSSI
  • Membrane Keypad
  • Optional High Gain YAGI, Class I, Div 1 and Class 1, Div 2 rated

          

 

 

 

 

 

 



Bentek Systems
Bentek Systems
SCADA & Telemetry Solutions

504 - 42nd Ave.S.E.
Calgary, Alberta, Canada T2G   1Y6
(403)  243-5135  Fax: (403) 243-5165
www.scadalink.com