SCADA Applications
SCADALink 900-MB pserv150thumb.jpg (2556 bytes)

 


Oil & Gas

  • Integrated RTU & Radiomodem in one compact package for cost effective SCADA & Telemetry applications
  • Modbus RTU Protocol
  • 4 Inputs (Analog or Digital)  4 Outputs
  • License Free Operation


Pumpjack / Screwpump  Monitoring & Shutdown

 


 Digital outputs can be used to start / stop pump jack. Digital inputs can be used to monitor well status (Run, ESD). Its compact size allows the SCADALink 900-MB RTU / radiomodem to be installed inside a motor starter enclosure. The 900-MB can also be used with utility or gas powered pumps.

Water Disposal High Level Shutdown Use the 900-MB to remotely shutdown transfer and production pumps on high tank levels.

PLC / VFD / Flowcomputer/ Power Monitoring Equipment SCADA Communications The SCADALink 900-MB with its RS232 and RS485 ports can  easily interface to wide range of control equipment including SCADA Hosts, PLC’s, RTU’s, VFD's, Flow Computers & Power Meters.

Water/CO2 Injection Well Status Monitoring A solar powered SCADALink 900-MB can be used to monitor: an annulus pressure switch (Digital Input), injection pressure (Analog Input), flow rate (Analog Input) or flow totalization (Pulse Input) on the injection well.

Pipeline Terminal Valve Control The SCADALink RTU (SCADALink 900-MB w/o radio) with its compact size can be installed inside a Class 1 Div 1 valve controller enclosure in pipeline terminal. Each valve has 2 inputs (OPEN, CLOSE status) and two outputs (OPEN and CLOSE commands) . The RTU can be multidropped with a RS485 network, thus allowing multiple valve controller to be controlled by the same pair of wires, rather than running hardwire to each valve.

Remote Valve Control A remote throttling valve could be controlled using a single analog output. An analog input can be used to monitor the actual valve position. Digital inputs can be used for Local/Remote Indication.

Gas Detection Remote detection of H2S level (Analog Input) or alarm (Digital Input).

Wellhead Pressure Use a single Analog Input to measure wellhead pressure.

Compressor Alarms Monitor compressor run status.

Wireless Tank Gauging Monitor level transmitter or switches from remote production tanks. Save on trenching.

Powerline Recloser Monitor status of Recloser. Remotely trips Recloser to disconnect load.

Repeater Use a license-free link to extend coverage.