Solaris 3000 Hybrid Solar Off-Grid Power System
SOLARIS 3000 is a Modular Off-Grid Solar Hybrid Power System designed to provide UPS backed DC (24 / 48 VDC) and AC (120 VAC) power for critical Remote Oil & Gas, Mining, and Telecommunications Applications. -
Industrial Solar Panels
Class I Div 2, 12VDC and 24VDC Solar Power Systems. -
PowerGen Generators
PowerGen Generators can generate up 5650 Watts of 24VDC Power from Propane, Natural Gas or Wellhead Gas making Ideal for Critical Remote Site Applications.
Overview
Bentek Systems stocks and supplies solar charge regulators for industrial applications. These are rated for Hazardous Locations – Class 1, Division 2 Groups A-D. We also supply AGM batteries built for the harsh Canadian climate, which continue to operate at -40C. The advanced AGM design ensures minimal voltage drop and more power availability. They are spill-proof and maintenance-free, ideal for remote installations.
Features & Specs
Morningstar Solar Regulators
- Class 1, Div 2 Groups A-D
- Extremely High Reliability
- Longer Battery Life
- Designed for Harsh Environments
- Easy to Install and Use
- 100% solid state
- Series design (not shunt)
- True 0 to 100% PWM duty cycle
- Setpoint accuracy 12V: +/-25mV; 24V: +/-48mV
- Fully encapsulated in epoxy potting
- Marine rated terminals / anodized case
- Temperature compensation
- Sealed / Flooded battery select
- Parallel for 40 amps or more
Versions | Solar Current | Load Current | System Voltage | LVD |
SS-10-12V | 10A | 10A | 12V | |
SS-10L-12V | 10A | 10A | 12V | • |
SS-10L-24V | 10A | 10A | 24V | • |
SS-20L-12V | 20A | 20A | 12V | • |
SS-20L-24V | 20A | 20A | 24V | • |
Batteries
Nominal Voltage | 12 volts |
Nominal Capacity | 121 Ah |
Internal Resistance (approx.) | 5mΩ |
Approximate Weight | 63.93 lbs (29kgs) |
Charge Method | Constant Voltage |
Float Use (Control Voltage) | 13.6 – 13.8 V |
Electrolyte | AGM |
Weight | 64lb |
Terminal Type | Internal Thread |
AGM Operational Temperature | |
Discharge | -40°C to 60°C |
Charge | -20°C to 50°C |
AGM Storage Temperature | -20°C to 45°C |
Temperature Dependency of Caoacity | (20 hour rate) |
40°C | 102% |
25°C | 100% |
0°C | 85% |
-15°C | 65% |
Related Products & Accessories
Remote Power
Power Supplies and Power Converters
-
SCADALink PSC Industrial DC-DC Converter Series
Class I Div 2, 10-30VDC input for a wide-range of DC-powered equipment. 12V, 24V, 5V, 6V, 7.5V, 9V. -
SCADALink PSC-12 24VDC to 12VDC Converter – Class I Div 2
24VDC to 12VDC Converter, Class I Div 2, DIN Rail Mount. -
SCADALink PSC-24 12VDC to 24VDC Converter – Class I Div 2
12VDC to 24VDC Converter, Class I Div 2, DIN Rail Mount. -
CJT BC1205 & BC2403 Converters
12VDC Class I Div 2 Power Supply / Charger.
SCADA Enclosures / Panels
Battery Enclosures / Boxes