Menu

SAT100 RTU

SAT100 Satellite RTU Systems

Complete and Ready to Install RTU Packages for Remote Monitoring and Control Systems.  Select required Airtime Package & Options.

ItemPart No.DescriptionNote
1SAT100 - KITSAT100 Satellite RTU Kit with TB-1 Termination Board B1 to be mounted in user supplied panelA
2SAT100 - RTU - DC - JBSAT100 Satellite RTU Kit with "6" x 6" x 6" NEMA4 Enclosure, 10-30 VDC Input, TB1 with 4 DIA
3ASAT100 - RTU - 12VDC SAT100 Satellite RTU Kit with 8" x 8" x 8" NEMA4X Fiberglas Enclosure, Quick Connect Wiring for 4 AI/Power
3BSAT100 - RTU - DC2DC SAT100 Satellite RTU Kit with 8" x 8" x 8" NEMA4X Fiberglas Enclosure, DC to DC , Quick Connect Wiring for 4 AI/PowerB
4SAT100 - GW - RTU -C
5SAT100 RTU - DC SAT100 Satellite RTU Kit with 18" x 16" x 10" NEMA4 Fiberglas Enclosure. 24VDC PowerD
6SAT100 RTU - AC - BKSAT100 Satellite RTU Kit with 20" x 20" x 10" NEMA4 Enclosure, 24VDC, 2A Power Supply with 1.3AH Battery BackupE
7SAT100 - SOL - RTU - 3012SAT100 Satellite RTU Kit with 18" x 16" x 10" NEMA4 Fiberglas Enclosure. 30W Solar, 37AH Battery, 12VDC PowerF
8SAT100 - SOL - RTU - 3024 SAT100 Satellite RTU Kit with 18" x 16" x 10" NEMA4 Fiberglas Enclosure. 30W Solar, 37AH Battery, 24VDC PowerF, G
9SAT100-SOL-5SAT100 Satellite RTU 14” x 12” x 6” NEMA4X with 5W Solar Panel

Notes

A. Package 2 used remotes sites where there is 10-30 VDC power available and up to 4 additional alarm contacts required.

B. Can include Optional DC to DC converter to generate 24VDC loop power required for 4-20ma Instruments.

C.

D. Package 3 used for remote sites where 10-30 VDC Power source available. Room to add analog transmitter inputs, wireless sensors, and additional I/O, controllers.

E. Package 4 used for remote sites where AC line power is available. The system is 24VDC with integral battery backup.

F. Package 5 and 6 are for Remote Sites without Line Power. Additional solar panel and battery may be required for applications with additional instruments.

G. Includes DC to DC converter to generate 24VDC loop power required for 4-20ma Instruments.

 

 

SAT110 RTU

SAT110 RTU Systems

The following SAT110 RTU packages are complete and ready to install systems. The SAT110 is a battery powered system and is available in 3 simple configurations.

ItemPart No.DescriptionNote
1SAT110SAT110 Battery Powered Satellite RTU/Alarm CalloutA
2SAT110 - KIT1SAT110 Battery Powered Satellite RTU/Alarm Callout and Termination BoardB
3SAT110 RTUSAT110 Battery Powered Satellite RTU/Alarm Callout with Junction BoxB, C

Notes

A. Item 1 used for the compressor and engine monitoring applications using internal vibration sensor.

B. Item 2,3 used for applications where up 3 alarm contacts (pressure switch, RUN, ALARM) are to be wired in. DC power can be connected to eliminate the need for battery replacement.

C. Item 3 includes an enclosure for Termination Board.

 

SAT120 RTU

SAT120 RTU Systems

The following SAT120 RTU packages are complete and ready to install systems. All SAT120 RTU systems come standard as shown with both an omnidirectional cellular antenna with 15'antenna cable and satellite antenna with 15' cable. This helps ensure antenna clearance of site obstructions. For some applications customer may require longer antenna cables and cellular YAGI antennas.

ItemPart No.DescriptionNote
1SAT-120-RTU-KIT1SAT120 Dual Mode Satellite/Cellular RTU Kit with TB-1 Termination Board B1 to be mounted in user supplied panelA
2SAT-120-RTU-DCSAT120 Dual Mode Satellite/Cellular RTU with TB1, Integral Panel Mount Antennas in 14" x 12" x 6" NEMA4X Enclosure
B
3C
4SAT120 RTU-DC
(DC Powered RTU System)
SAT120 Dual Mode Satellite/Cellular RTU - 20" x 20" x 10" NEMA4 Enclosure TB1 Terminaition Board, 10-30VDC Input, 24VDC PowerD
5SAT120 RTU-AC-BK
(AC Powered RTU System)
SAT120 Dual Mode Satellite/Cellular RTU - 20" x 20" x 10" NEMA4 Enclosure with SAT120, TB1 Terminaition Board, 10-30VDC Input, 24VDC PowerE
6 SAT120 RTU-SOL-5024SAT120 Satellite RTU Kit with 20" x 20" x 10" NEMA4 Enclosure. 50W Solar, 37AH Battery, 24VDC PowerF

Notes

A. SAT120 Dual Mode Satellite/Cellular RTU Kit with TB-1 Termination Board B1 to be mounted in the user-supplied panel

B.

C.

D. SAT120 Dual Mode Satellite/Cellular RTU - 20" x 20" x 10" NEMA4 Enclosure TB1 Termination Board, 10-30VDC Input, 24VDC Power

E. SAT120 Dual Mode Satellite/Cellular RTU - 20" x 20" x 10" NEMA4 Enclosure with SAT120, TB1 Termination Board, 10-30VDC Input, 24VDC Power

F. SAT120 Satellite RTU Kit with 20" x 20" x 10" NEMA4 Enclosure. 50W Solar, 37AH Battery, 24VDC Power

 

 

SAT130 RTU

SAT130 RTU Systems

The following SAT130 RTU packages are completely ready to install systems. All SAT130 RTU systems come standard as shown with both an omnidirectional cellular antenna with 15'antenna cable and satellite antenna with 15' cable. This helps ensure antenna clearance of site obstructions. For some applications customer may require longer antenna cables and cellular YAGI antennas.

ItemPart No.DescriptionNote
1SAT130 KITSAT130 Dual Mode Satellite/Cellular Kit with TB2, Terminal Block TB2 (for mounted in user supplied panel).A
2SAT130–PFP02SAT130 Sat/Cellular RTU Modem with TB2 Termination Board, Multi-mode Antenna, 8” x 8” x 8” Enclosure, Wiring/Fusing
(no lightning arrester/cable required)
B
3SAT130–PFP3SAT130 Sat/Cellular RTU Modem with TB2 Termination Board, Multi-mode Antenna, 8” x 8” x 8” Enclosure, Wiring/Fusing, POE Splitter, Ethernet Connector Quick Connector, 6” Ethernet Cable
(no lightning arrester/cable required)
C
4SAT130-HUBD
5SAT130-HUB-HMIE
6SAT130 RTU-DC (DC Powered RTU System)SAT130 Dual Mode Satellite/Cellular RTU - 18" x 16" x 8" NEMA4X Enclosure TB1 Termination Board, 10-30VDC Input, 24VDC Power.
SAT130 RTU-DC
F
7SAT130 RTU-AC-BK
(AC Powered RTU System)
SAT130 Dual Mode Satellite/Cellular RTU - 18" x 16" x 8" NEMA4 Enclosure with SAT130, TB1 Termination Board, 120 VDC AC with 24VDC Battery Backup.
SAT130 RTU-AC-BK
G
8SAT130 RTU-SOL-5024SAT130 Satellite RTU Kit with 20" x 20" x 10" NEMA4 Enclosure. 2x 12VDC 30W Solar Panel, 100AH Battery, 24VDC Power.
SAT130 RTU-SOL-5024
D

Notes

A. SAT130 Dual Mode Satellite/Cellular Kit with TB2, Terminal Block TB2 (for mounted in user-supplied panel)

B.

C. SAT130 with Panel Mount Antennas, 8” x 8” x 8” NEMA 4 Enclosure, Optional POE Power (This package can be used to simplify SAT130 antenna wiring).

D. SAT130 Satellite RTU Kit with 20" x 20" x 10" NEMA4 Enclosure. 2x 12VDC 30W Solar Panel, 100AH Battery, 24VDC Power\

E.

F. SAT130 Dual Mode Satellite/Cellular RTU - 18" x 16" x 8" NEMA4X Enclosure TB1 Termination Board, 10-30VDC Input, 24VDC Power

G. SAT130 Dual Mode Satellite/Cellular RTU - 18" x 16" x 8" NEMA4 Enclosure with SAT130, TB1 Termination Board, 120 VDC AC with 24VDC Battery Backup

 

 

 

 

RTU Options

RTU Options

The following table shows options for the SAT1xx RTU Packages.

ItemPart No.DescriptionNote
Certification
1CERT-C1D2Class I Div 2 CertificationA
Panel Accessories
2RTU-INSULPanel Insulation for Cold Temperature OperationB
Local Operator Interface
3LCD / Keypad 4 Line x 20 Character Backlit LCD/Keypad Option Provides Local Onsite Display of Tag ValuesC
Modbus Ethernet Gateway more...
4SCADALink IP-100SCADALink Modbus Ethernet Gateway, Class I Div 2D
5SCADALink DC-100Powerful and Easy-to-Configure Modbus Data Concentrator, Class I Div 2D
RTU I/O Expansion
6SCADALink-RIOModbus RTU Serial Gateway Class I Div 2E
7SCADALink AI44 Analog Inputs (4-20mA)E
8SCADALink AO44 Analog Outputs (4-20mA)E
9SCADALink DI88 Digital InputsE
10SCADALink DO88 Digital Outputs (Relays)E
Power Supply Options
11AC Power with Battery BackupAC Powered Systems can be provided with 12 or 24 VDC Battery BackupF
12Solar PowerSolar Power and Battery SystemsI
13PSC 24 12 to 24vdc din24 VDC InverterDC to DC Inverter 24VDC Output (4A) from 10-30 VDC InputJ
Antenna Options
14Antenna / CablingAntenna with Antenna Cable SystemsK
Mounting Accessories
15RTU Stand for Mounting of SatSCADA RTU SystemsL
16RTU Stand for Solar Powered RTU SystemsM
17PIPE-ALUM-1.5 x 66' 1.5" Sched 80 Alum Pipe Mast for Mounting Panel and AntennaeN
Wireless Sensors
18Sentinel GatewaySentinel Wireless Sensor Gateway StickO
19Sentinel Modbus RepeaterSentinel Wireless Sensor Modbus Repeater StickP
20Sentinel AnalogSentinel Analog WIreless NodeQ
21Sentinel DigitalSentinel Digital Wireless NodeQ
22Sentinel ModbusSentinel Modbus Wireless NodeQ
RTU, Data Logger, & EFM
23RTURTU Options to Provide Local ControlR
24Data LoggerDatalogger Options to Provide Onsite Data LoggingS
25EFMEFM and Flowmeters used for Flow MeasurementT
Mounting Option
26Pipe MountProvides Mounting of SatSCADA RTU Nodes to Pipe from 4"-10"
27Mounting SensorProvides Mounting of Wireless Sensor Nodes to Pipe from 4"-10"

Notes

A. Panel Certified for Class I Div 2 Operation.

B. For Operation in Cold Temperatures.

D. Provide Connect to Modbus TCP based Ethernet Devices in Field.

E. Module I/0 used for I/O Expansion for SAT1xx up to a maximum of 8 I/O Modules.

K. KHigh Gain YAGI and Field Line.

N. Pipe for Mounting Panel and Antennas.

O. Add Wireless Sensor Nodes to System.

Q. Wireless Sensor Nodes - See Sensor Options.

 

Airtime

Airtime & Hosting

The following standard Hosting and Airtime Packages are available for the SAT1xx Terminals.  Overage Charges for Additional Satellite and Cellular Airtime apply.

Custom Airtime Packages available.

ItemPart No.DescriptionNote
SatSCADA Hosting & Satellite/Cell Airtime
1SatSCADA-SAT25SatSCADA Hosting w/h 25K SatA
2SatSCADA-SAT100SatSCADA Hosting w/h 100K SatA
3SatSCADA-SAT100-CELL30SatSCADA Hosting w/h 100K Sat & 300 MB CellularB
4SatSCADA-CELL300SatSCADA Hosting with 300 MB CellularC
SatSCADA Airtime
5SatSCADA-AIR-SAT100SatSCADA Gateway with 100K SatE
6SatSCADA-AIR-SAT100-CELL300SatSCADA Airtime with 100K Sat & 300 MB Cellular
7SatSCADA-AIR-CELL300SatSCADA Airtime 300 MB Cellular

Notes

A. Alarm Callout and Daily Reporting.

B. Alarm Callout and Reporting to 4 - 12 Times Day.

C. Alarm Callout and Reporting.

D. Alarm Callout and Reporting - Cellular Data.

E. Use of Passthru Data Access.

SatSCADA Hosted SCADA

 

 

 

Services

Services

The following table shows provisioning and configuration service options offered. Configuration is based on application requirements supplied by the customer. Setup and testing ensure that terminal is fully tested prior to shipment and ready for operation.

ItemPart No.DescriptionNote
1SVC-SAT110-VIBProvision and Setup SAT110 for RUN-NO RUN Monitoring with VIB
2SVC-SAT1xx-IOProvision and Setup SAT1xx for Internal I/O
3SVC-SAT1xx-MOD10Provision and Setup SAT1xx for Modbus Device Polling < 10 Tags
4SVC-SAT1xx-MOD10+Provision and Setup SAT1xx for Modbus Device Polling >= 10 Tags
5SVC-SAT1xx-WGSetup Wireless Gateway for SAT1xx Terminal
6SVC-SAT1xx-CUSTOMCustom Setup and Testing for Customer Application

 

 

 

 

Sensor Options

Sensor / Instrumentation Options

The following table lists Sensor and Instrumentation options that can be provided for commonly supported SatSCADA Remote Monitoring Applications.

Wired and Wireless Instrumentation options are listed. Wireless Instrumentation Assemblies include Wireless Sensor Nodes, Mounting Kits, Junction Box, and Instrument. For Wireless Sensor Nodes Operation adds Wireless Gateway option in RTU panel configuration.

Instrumentation for Oil & Gas Applications Rated for hazardous areas as indicated.

ItemPart No.DescriptionNote
Wireless Sensor Nodes - Class I Div 1 Intrinically Safe (IS)
1WL-PT-xxxWireless Pressure Transmitter - Specify PSIA
2WL-TTWireless Temperature Transmitter
3WL-MCIIIWireless Turbine Flowmeter Systems (Use MCIII)
4WL-DIWireless Digital Input Interface (connect to Switch Inputs)B
5WL-ANAWireless Analog Sensor Node with Junction Box
6WL-MODWireless Modbus Sensor Node with Junction Box
WIreless Sensors Nodes
7WL-DI-FloatWireless Float Switch SystemA
8WL-DI-PSWWireless Pressure Switch Node c/w Pressure Switch
9WL-PSPressure Alarm Reporting - Class 1 Div 1
Instruments - Tank Level Monitoring
10INST-LT-MAGNO-420-MODLevel Transmitter Magnetostrictive Float - Class I Div I XP up to 96" spanC
11INST-LT-ULTRASUltrasonic Level Transmitter - Class I Div 1 IS - 4-20 ma
12INST-LT-420Level Transmitter Resistive Float - Class I Div IS up to 96" span
13INST-LT-SUB-420 Submersible Pressure Transmitter - Class I Div 1 IS - 4 -20 ma, Vented xxx PSI
14INST-FLOAT-SWITCH
Instruments - Water Measurement
15INST-LT-SUB-GAU-420Submersible Pressure Transmitter - Gauge Pressure - Vented - xxx PSID
16INST-LT-SUB-ABS-420Submersible Pressure Transmitter - Absolute Pressure - xxx PSI
17MC-III EXP Flow AnalyzerE
18SeaMetrics Flow MeterBattery Powered Ultrasonic Flowmeter with Pulse OutputF
Instruments - Gas Measurement
19Dynamic Fluid and Flow ComputerG

Notes

A. Complete Wireless Sensor Assembly.

B. Wireless Sensor Node and Junction Box - Instrument Required.

C. Petroleum Products/Chemical Storage Tank Level Monitoring.

D. Level Monitoring.

E. Flow Totalization.

F. Water Flow Measurement.

G. Gas Flow Measurement.