SCADALink RS485 Hub – Class I Div 2 Rated
Overview
SCADALink 485Hub – RS485 Hub
The SCADAlink 485HUB is a RS485 Hub designed for connecting RS485 field devices in rugged industrial applications. The DIN Rail mounted 485Hub features RS232/RS485 inputs and 3 isolated 2 wire RS485 output ports. The 485HUB features low power operation, wide voltage operation range (10-30 VDC) and Class I Div 2 rating.
RS232 and RS485 Inputs
The RS485Hub has RS232 and RS485 inputs allowing direct connection from PLC, RTU, Computers, Ethernet to Serial Terminal Servers and Modems to RS485 field instruments.
The 485HUB has an RS485 bus that allows multiple 485HUBs to be bussed together to expand the hub from 3 to 6, & 9 ports.
Operation
All data on the RS232 and RS485 input port is transmitted to the RS485 Hub ports. Receive traffic on RS485 Hub Ports are transmitted only to the input port. Up to 32 RS485 devices can be connected to each hub port. Each hub output port is individually isolated to protect from surges of any port affecting equipment on other ports. Isolation and independent drivers on each port minimize device loading and end of line termination issues affecting RS485 communication. Even a wiring fault on an individual hub port will not affect communications on other ports. Since the RS485 hub ports are isolated, problems on a single hub port can be easily isolated and resolved.
Simple Terminal Block Wiring
Each of the 3 RS485 Hub Ports is terminated on its own individual removable connector. RS485 field wiring can be connected directly to the removable connectors. Individual RS485 connectors can be easily disconnected to isolate and troubleshoot a specific connection.
A USB maintenance port, when connected, overrides the input port, allowing easy troubleshooting.
RS485 Star Wiring Network Topology
The 485HUB is designed to connect longer RS485 wiring runs in a star topology from a central location. Each hub port is an independently isolated channel. Isolation and independent channels prevent grounding, device loading, termination problems, signal loss, and noise on one RS485 connection from affecting the RS485 network. A Hub topology simplifies system troubleshooting.
Isolation
The 485HUB is ideal for applications where there are multiple remote RS485 connected field instruments. Independently isolated hub ports allow wiring connectivity in a simple star network topology to ensure higher reliability RS485 networking and increasing uptime and minimizing commissioning, maintenance, and troubleshooting costs.
Long RS485 instrument cable runs should use an individual RS485 hub port for maximum isolation and protection against surge and lightning damage to equipment in the connected network.
The length of each individual RS485 run can exceed 4000′.
USB Input Override
The 485HUB has USB Input Override mode where the input is bypassed by the USB when connected, allowing maintenance access to the RS485 connected devices with the removal of RS485 wiring. This ideal for maintenance and configuration of RS485 instruments.
Specifications
RS485 Hub Features
- Industrial RS-232/RS-485 to Isolated 3 Port 2 Wire RS-485 HUB
- USB Input Port – USB Override
- Terminal Block Field Connections
- DIN Rail Mount
- Class 1 Div 2 Certification Pending
Specifications
Input Power | 10 to 30 VDC – 200mA Max, 1W Avg |
Baud Rate | 1200 – 115,200 (Selectable) |
Input | |
RS-232: | TX, RX, GND, RTS |
RS-485: | + , – , GND |
USB: | Standard USB B-Type (Drivers) |
Output | |
3 Isolated Rs-485 Ports: | + , – , GND |
Termination | 120 Ohms (Selectable) |
Isolation | >2000V |
Mounting | 35mm DIN-rail |
Dimensions | 99m(L) x 23mm(W) x 116mm(H) |
Temperature | -40 to 70C |
Certification | Class I Div 2, Group C, D T3C Suitable for Use in Class 1 Zone 2, IIB T3C |
Documentation
Related Products
Data Communication
-
RS232 to RS485 Converter – Class I Div 2 Rated
The TISC-485 is a RS232 to RS485 Converter designed for Industrial applications that is Class I Div 2 Certification and DIN Rail Mounted. -
SCADALink RS485 Hub – Class I Div 2 Rated
The SCADALink RS485HUB is designed for connecting RS485 field instruments to SCADA, PLC, and DCS Systems in Oil and Gas Production and Pipeline Applications. -
SCADALink SPL3 RS232 Splitter – Class I Div 2
Passive RS232 Splitter. DIN-rail mounted and Class I Div 2. It enables a number of Multi dropped Serial Devices to share the same Modem or Master. -
SCADALink SPL4-TB RS232 Splitter – Class I Div 2
The SCADALink SPL4-TB is a passive 4 port RS232 Modem Splitter designed for Industrial applications with DIN Rail Mount and Class I Div 2 Ratings, -
SCADALink SCADASwitch SS10 Modbus Multiplexer
The SS10 is used for Modbus Multiplexing, RS232 Switching, RS485 Conversion and/or where Radio Keying is required. Low power, DIN rail mount, Class I Div 2. -
SCADALink SS20 SCADASwitch Modbus Multiplexer (Mux)
The SS20 is a datacom interface device for SCADA & Industrial control applications where Modbus Multiplexing, RS232 Switching, RS485 Conversion and/or Radio Keying is required. -
SCADALink USC – USB to RS232 / RS485 Converter
USB to RS232 / RS485 Converter designed for rugged industrial field applications.
SCADA Terminal Server